Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Release characteristicD
Rated insulation voltage Ui500V
Built-in depth44mm
Pollution degree2
Current limiting class-
Width in number of modular spacings2
Frequency50 - 60Hz
Rated current32A
Rated voltage400V
Over voltage category-
Degree of protection (IP)IP20
Ambient temperature during operating- - -°C
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Number of poles (total)2
Suitable for flush-mounted installationYes
Connectable conductor cross section solid-core- - -mm²
Number of protected poles2
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403741 | TX3 AUTOM OSIG 2P D32 6KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Release characteristic

D

Rated insulation voltage Ui

500V

Built-in depth

44mm

Pollution degree

2

Current limiting class

-

Width in number of modular spacings

2

Frequency

50 .. 60Hz

Rated current

32A

Rated voltage

400V

Over voltage category

-

Degree of protection (IP)

IP20

Ambient temperature during operating

- .. -°C

Additional equipment possible

Concurrently switching neutral conductor

Number of poles (total)

2

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Number of protected poles

2

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.