Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Suitable for flush-mounted installationYes
Built-in depth44mm
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Rated current13A
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Ambient temperature during operating- - -°C
Pollution degree2
Rated voltage400V
Release characteristicD
Degree of protection (IP)IP20
Current limiting class-
Frequency50 - 60Hz
Number of protected poles3
Rated insulation voltage Ui500V
Over voltage category-
Number of poles (total)3
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403754 | TX3 AUTOM OSIG 3P D13 6KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Suitable for flush-mounted installation

Built-in depth

44mm

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated current

13A

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

3

Ambient temperature during operating

- .. -°C

Pollution degree

2

Rated voltage

400V

Release characteristic

D

Degree of protection (IP)

IP20

Current limiting class

-

Frequency

50 .. 60Hz

Number of protected poles

3

Rated insulation voltage Ui

500V

Over voltage category

-

Number of poles (total)

3

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.