Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Concurrently switching neutral conductorYes
Rated current4A
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating- - -°C
Connectable conductor cross section multi-wired- - -mm²
Suitable for flush-mounted installationYes
Pollution degree2
Frequency50 - 60Hz
Width in number of modular spacings4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Current limiting class-
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Over voltage category-
Rated insulation voltage Ui500V
Release characteristicD
Number of protected poles3
Rated voltage400V
Built-in depth44mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403767 | TX3 AUTOM OSIG 4P D4 6KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Concurrently switching neutral conductor

Rated current

4A

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

- .. -°C

Connectable conductor cross section multi-wired

- .. -mm²

Suitable for flush-mounted installation

Pollution degree

2

Frequency

50 .. 60Hz

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Current limiting class

-

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Over voltage category

-

Rated insulation voltage Ui

500V

Release characteristic

D

Number of protected poles

3

Rated voltage

400V

Built-in depth

44mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.