Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Rated voltage400V
Rated current13A
Degree of protection (IP)IP20
Voltage typeAC
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Current limiting class-
Pollution degree2
Release characteristicD
Width in number of modular spacings4
Over voltage category-
Number of protected poles3
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Ambient temperature during operating- - -°C
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)4
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403771 | TX3 AUTOM OSIG 4P D13 6KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Rated voltage

400V

Rated current

13A

Degree of protection (IP)

IP20

Voltage type

AC

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Current limiting class

-

Pollution degree

2

Release characteristic

D

Width in number of modular spacings

4

Over voltage category

-

Number of protected poles

3

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Ambient temperature during operating

- .. -°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

4

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.