Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated impulse withstand voltage Uimp4kV
Over voltage category-
Frequency50 - 60Hz
Suitable for flush-mounted installationYes
Release characteristicB
Rated voltage230V
Degree of protection (IP)IP20
Pollution degree2
Width in number of modular spacings2
Connectable conductor cross section solid-core- - -mm²
Rated current3A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Number of protected poles1
Built-in depth44mm
Rated insulation voltage Ui500V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorYes
Number of poles (total)2
Connectable conductor cross section multi-wired- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404093 | TX3 AUTOM OSIG 1P+N B3 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Over voltage category

-

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Release characteristic

B

Rated voltage

230V

Degree of protection (IP)

IP20

Pollution degree

2

Width in number of modular spacings

2

Connectable conductor cross section solid-core

- .. -mm²

Rated current

3A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Number of protected poles

1

Built-in depth

44mm

Rated insulation voltage Ui

500V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Number of poles (total)

2

Connectable conductor cross section multi-wired

- .. -mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.