Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated current10A
Frequency50 - 60Hz
Voltage typeAC
Rated voltage230V
Built-in depth44mm
Current limiting class3
Over voltage category-
Rated insulation voltage Ui500V
Width in number of modular spacings2
Release characteristicB
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired- - -mm²
Number of protected poles1
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Number of poles (total)2
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404096 | TX3 AUTOM OSIG 1P+N B10 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated current

10A

Frequency

50 .. 60Hz

Voltage type

AC

Rated voltage

230V

Built-in depth

44mm

Current limiting class

3

Over voltage category

-

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Release characteristic

B

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

- .. -mm²

Number of protected poles

1

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Number of poles (total)

2

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.