Technical specifications

Rated insulation voltage Ui500V
Built-in depth44mm
Over voltage category-
Voltage typeAC
Pollution degree2
Frequency50 - 60Hz
Current limiting class3
Rated voltage400V
Release characteristicB
Number of protected poles2
Rated current2A
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Ambient temperature during operating- - -°C
Number of poles (total)2
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404106 | TX3 AUTOM OSIG 2P B 2A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated insulation voltage Ui

500V

Built-in depth

44mm

Over voltage category

-

Voltage type

AC

Pollution degree

2

Frequency

50 .. 60Hz

Current limiting class

3

Rated voltage

400V

Release characteristic

B

Number of protected poles

2

Rated current

2A

Concurrently switching neutral conductor

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Ambient temperature during operating

- .. -°C

Number of poles (total)

2

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.