Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Number of protected poles2
Concurrently switching neutral conductorNo
Release characteristicB
Suitable for flush-mounted installationYes
Width in number of modular spacings2
Over voltage category-
Connectable conductor cross section multi-wired- - -mm²
Rated voltage400V
Connectable conductor cross section solid-core- - -mm²
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Rated current3A
Ambient temperature during operating- - -°C
Voltage typeAC
Frequency50 - 60Hz
Pollution degree2
Current limiting class3
Additional equipment possibleYes
Built-in depth44mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404107 | TX3 AUTOM OSIG 2P B 3A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Number of protected poles

2

Concurrently switching neutral conductor

Release characteristic

B

Suitable for flush-mounted installation

Width in number of modular spacings

2

Over voltage category

-

Connectable conductor cross section multi-wired

- .. -mm²

Rated voltage

400V

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Rated current

3A

Ambient temperature during operating

- .. -°C

Voltage type

AC

Frequency

50 .. 60Hz

Pollution degree

2

Current limiting class

3

Additional equipment possible

Built-in depth

44mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.