Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Current limiting class3
Built-in depth44mm
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Number of protected poles2
Pollution degree2
Voltage typeAC
Over voltage category-
Connectable conductor cross section solid-core- - -mm²
Release characteristicB
Rated current10A
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated insulation voltage Ui500V
Rated voltage400V
Ambient temperature during operating- - -°C
Additional equipment possibleYes
Number of poles (total)2
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404110 | TX3 AUTOM OSIG 2P B 10A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Current limiting class

3

Built-in depth

44mm

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Number of protected poles

2

Pollution degree

2

Voltage type

AC

Over voltage category

-

Connectable conductor cross section solid-core

- .. -mm²

Release characteristic

B

Rated current

10A

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated insulation voltage Ui

500V

Rated voltage

400V

Ambient temperature during operating

- .. -°C

Additional equipment possible

Number of poles (total)

2

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.