Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Current limiting class3
Rated current13A
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui500V
Release characteristicB
Built-in depth44mm
Suitable for flush-mounted installationYes
Number of protected poles3
Number of poles (total)3
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating- - -°C
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Over voltage category-
Pollution degree2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404125 | TX3 AUTOM OSIG 3P B 13A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Current limiting class

3

Rated current

13A

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

500V

Release characteristic

B

Built-in depth

44mm

Suitable for flush-mounted installation

Number of protected poles

3

Number of poles (total)

3

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

- .. -°C

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Over voltage category

-

Pollution degree

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Connectable conductor cross section multi-wired

- .. -mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.