Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency50 - 60Hz
Built-in depth44mm
Rated insulation voltage Ui500V
Release characteristicB
Rated voltage400V
Voltage typeAC
Rated current2A
Concurrently switching neutral conductorYes
Pollution degree2
Degree of protection (IP)IP20
Number of protected poles3
Width in number of modular spacings4
Current limiting class3
Additional equipment possibleYes
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)4
Ambient temperature during operating- - -°C
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404148 | TX3 AUTOM OSIG 4P B 2A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

44mm

Rated insulation voltage Ui

500V

Release characteristic

B

Rated voltage

400V

Voltage type

AC

Rated current

2A

Concurrently switching neutral conductor

Pollution degree

2

Degree of protection (IP)

IP20

Number of protected poles

3

Width in number of modular spacings

4

Current limiting class

3

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

4

Ambient temperature during operating

- .. -°C

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.