Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationYes
Rated current4A
Rated voltage230V
Width in number of modular spacings1
Built-in depth44mm
Release characteristicC
Ambient temperature during operating- - -°C
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Number of protected poles1
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Current limiting class3
Additional equipment possibleYes
Frequency50 - 60Hz
Pollution degree2
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404166 | TX3 AUTOM OSIG 1P C 4A 10KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

4A

Rated voltage

230V

Width in number of modular spacings

1

Built-in depth

44mm

Release characteristic

C

Ambient temperature during operating

- .. -°C

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

3

Additional equipment possible

Frequency

50 .. 60Hz

Pollution degree

2

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA