Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated voltage400V
Built-in depth44mm
Rated current13A
Release characteristicC
Frequency50 - 60Hz
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Over voltage category-
Concurrently switching neutral conductorNo
Number of poles (total)2
Connectable conductor cross section multi-wired- - -mm²
Current limiting class3
Width in number of modular spacings2
Pollution degree2
Suitable for flush-mounted installationYes
Ambient temperature during operating- - -°C
Degree of protection (IP)IP20
Number of protected poles2
Additional equipment possibleYes
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core- - -mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404204 | TX3 AUTOM OSIG 2P C 13A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Built-in depth

44mm

Rated current

13A

Release characteristic

C

Frequency

50 .. 60Hz

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Over voltage category

-

Concurrently switching neutral conductor

Number of poles (total)

2

Connectable conductor cross section multi-wired

- .. -mm²

Current limiting class

3

Width in number of modular spacings

2

Pollution degree

2

Suitable for flush-mounted installation

Ambient temperature during operating

- .. -°C

Degree of protection (IP)

IP20

Number of protected poles

2

Additional equipment possible

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

- .. -mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.