Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Release characteristicC
Rated insulation voltage Ui500V
Built-in depth44mm
Frequency50 - 60Hz
Rated voltage400V
Voltage typeAC
Rated current16A
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Over voltage category-
Number of protected poles2
Current limiting class3
Width in number of modular spacings2
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired- - -mm²
Suitable for flush-mounted installationYes
Number of poles (total)2
Additional equipment possibleYes
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404205 | TX3 AUTOM OSIG 2P C 16A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Release characteristic

C

Rated insulation voltage Ui

500V

Built-in depth

44mm

Frequency

50 .. 60Hz

Rated voltage

400V

Voltage type

AC

Rated current

16A

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Over voltage category

-

Number of protected poles

2

Current limiting class

3

Width in number of modular spacings

2

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

- .. -mm²

Suitable for flush-mounted installation

Number of poles (total)

2

Additional equipment possible

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.