Rated voltage400V
Rated insulation voltage Ui500V
Current limiting class3
Built-in depth44mm
Frequency50 - 60Hz
Rated current6A
Release characteristicC
Voltage typeAC
Over voltage category-
Pollution degree2
Connectable conductor cross section multi-wired- - -mm²
Suitable for flush-mounted installationYes
Width in number of modular spacings4
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating- - -°C
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of protected poles3
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404235 | TX3 AUTOM OSIG 3P+N C6 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Rated insulation voltage Ui

500V

Current limiting class

3

Built-in depth

44mm

Frequency

50 .. 60Hz

Rated current

6A

Release characteristic

C

Voltage type

AC

Over voltage category

-

Pollution degree

2

Connectable conductor cross section multi-wired

- .. -mm²

Suitable for flush-mounted installation

Width in number of modular spacings

4

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

- .. -°C

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of protected poles

3

Additional equipment possible