Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Rated insulation voltage Ui500V
Voltage typeAC
Current limiting class3
Rated voltage400V
Release characteristicC
Frequency50 - 60Hz
Rated current50A
Pollution degree2
Width in number of modular spacings4
Number of protected poles3
Ambient temperature during operating- - -°C
Suitable for flush-mounted installationYes
Over voltage category-
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired- - -mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

404261 | TX3 AUTOM OSIG 4P C 50A 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Rated insulation voltage Ui

500V

Voltage type

AC

Current limiting class

3

Rated voltage

400V

Release characteristic

C

Frequency

50 .. 60Hz

Rated current

50A

Pollution degree

2

Width in number of modular spacings

4

Number of protected poles

3

Ambient temperature during operating

- .. -°C

Suitable for flush-mounted installation

Over voltage category

-

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

- .. -mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.