Built-in depth44mm
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Rated voltage230V
Voltage typeAC
Concurrently switching neutral conductorNo
Number of protected poles1
Degree of protection (IP)IP20
Width in number of modular spacings1
Current limiting class3
Pollution degree2
Over voltage category-
Connectable conductor cross section solid-core1.5 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 70°C
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated current20A
Release characteristicB
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407433 | Aut.osig. DX3 1P B20 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Rated voltage

230V

Voltage type

AC

Concurrently switching neutral conductor

Number of protected poles

1

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Current limiting class

3

Pollution degree

2

Over voltage category

-

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 70°C

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated current

20A

Release characteristic

B

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA