Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Release characteristicB
Rated current25A
Frequency50 - 60Hz
Rated voltage230V
Voltage typeAC
Over voltage category-
Rated insulation voltage Ui500V
Current limiting class3
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1.5 - 25mm²
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 70°C
Number of poles (total)1
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core1.5 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles1
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407434 | AUT.OSIG. DX3 1P B25 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Release characteristic

B

Rated current

25A

Frequency

50 .. 60Hz

Rated voltage

230V

Voltage type

AC

Over voltage category

-

Rated insulation voltage Ui

500V

Current limiting class

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 70°C

Number of poles (total)

1

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

1

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.