Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Current limiting class3
Release characteristicB
Frequency50 - 60Hz
Rated current20A
Over voltage category-
Voltage typeAC
Rated insulation voltage Ui500V
Rated voltage400V
Number of protected poles2
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section solid-core1.5 - 35mm²
Suitable for flush-mounted installationYes
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407510 | AUT.OSIG. DX3 2P B20 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Current limiting class

3

Release characteristic

B

Frequency

50 .. 60Hz

Rated current

20A

Over voltage category

-

Voltage type

AC

Rated insulation voltage Ui

500V

Rated voltage

400V

Number of protected poles

2

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Additional equipment possible

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section solid-core

1.5 .. 35mm²

Suitable for flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.