Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated voltage400V
Built-in depth44mm
Rated current1A
Frequency50 - 60Hz
Additional equipment possibleYes
Current limiting class3
Connectable conductor cross section multi-wired1.5 - 25mm²
Number of protected poles3
Connectable conductor cross section solid-core1.5 - 35mm²
Rated impulse withstand voltage Uimp4kV
Release characteristicB
Ambient temperature during operating-25 - 70°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Pollution degree2
Suitable for flush-mounted installationYes
Number of poles (total)3
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Width in number of modular spacings3
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407554 | AUT.OSIG. DX3 3P B1 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated voltage

400V

Built-in depth

44mm

Rated current

1A

Frequency

50 .. 60Hz

Additional equipment possible

Current limiting class

3

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Number of protected poles

3

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Release characteristic

B

Ambient temperature during operating

-25 .. 70°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Pollution degree

2

Suitable for flush-mounted installation

Number of poles (total)

3

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Width in number of modular spacings

3

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA