Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings1
Rated voltage230V
Degree of protection (IP)IP20
Release characteristicC
Frequency50 - 60Hz
Rated current20A
Voltage typeAC
Built-in depth44mm
Current limiting class3
Over voltage category-
Number of protected poles1
Connectable conductor cross section multi-wired1.5 - 25mm²
Pollution degree2
Suitable for flush-mounted installationYes
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core1.5 - 35mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of poles (total)1
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407671 | AUT.OSIG. DX3 1P C20 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings

1

Rated voltage

230V

Degree of protection (IP)

IP20

Release characteristic

C

Frequency

50 .. 60Hz

Rated current

20A

Voltage type

AC

Built-in depth

44mm

Current limiting class

3

Over voltage category

-

Number of protected poles

1

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Pollution degree

2

Suitable for flush-mounted installation

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

1.5 .. 35mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of poles (total)

1

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible