Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Over voltage category-
Release characteristicC
Voltage typeAC
Frequency50 - 60Hz
Degree of protection (IP)IP20
Pollution degree2
Number of protected poles2
Rated voltage400V
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Current limiting class3
Width in number of modular spacings2
Built-in depth44mm
Suitable for flush-mounted installationYes
Rated current20A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Number of poles (total)2
Connectable conductor cross section solid-core1.5 - 35mm²
Connectable conductor cross section multi-wired1.5 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407801 | AUT.OSIG. DX3 2P C20 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Over voltage category

-

Release characteristic

C

Voltage type

AC

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Pollution degree

2

Number of protected poles

2

Rated voltage

400V

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Current limiting class

3

Width in number of modular spacings

2

Built-in depth

44mm

Suitable for flush-mounted installation

Rated current

20A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Number of poles (total)

2

Connectable conductor cross section solid-core

1.5 .. 35mm²

Connectable conductor cross section multi-wired

1.5 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.