Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated current25A
Release characteristicC
Frequency50 - 60Hz
Rated voltage400V
Built-in depth44mm
Voltage typeAC
Over voltage category-
Pollution degree2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Degree of protection (IP)IP20
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Connectable conductor cross section multi-wired1.5 - 25mm²
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section solid-core1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Current limiting class3
Width in number of modular spacings2
Suitable for flush-mounted installationYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407802 | AUT.OSIG. DX3 2P C25 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Rated current

25A

Release characteristic

C

Frequency

50 .. 60Hz

Rated voltage

400V

Built-in depth

44mm

Voltage type

AC

Over voltage category

-

Pollution degree

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Degree of protection (IP)

IP20

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section solid-core

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Current limiting class

3

Width in number of modular spacings

2

Suitable for flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.