Technical specifications

Built-in depth44mm
Voltage typeAC
Current limiting class3
Release characteristicC
Connectable conductor cross section solid-core1.5 - 35mm²
Suitable for flush-mounted installationYes
Over voltage category-
Frequency50 - 60Hz
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 25mm²
Degree of protection (IP)IP20
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated insulation voltage Ui500V
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Rated current50A
Rated voltage400V
Number of protected poles3
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407864 | AUT.OSIG. DX3 3P C50 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Voltage type

AC

Current limiting class

3

Release characteristic

C

Connectable conductor cross section solid-core

1.5 .. 35mm²

Suitable for flush-mounted installation

Over voltage category

-

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Concurrently switching neutral conductor

Additional equipment possible

Rated insulation voltage Ui

500V

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Rated current

50A

Rated voltage

400V

Number of protected poles

3

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA