  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency50 - 60Hz
Over voltage category-
Built-in depth44mm
Rated voltage400V
Pollution degree2
Current limiting class3
Rated insulation voltage Ui500V
Voltage typeAC
Release characteristicC
Rated current1A
Degree of protection (IP)IP20
Width in number of modular spacings4
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Number of protected poles3
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Connectable conductor cross section solid-core1.5 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Suitable for flush-mounted installationYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407920 | AUT.OSIG. DX3 4P C1 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency

50 .. 60Hz

Over voltage category

-

Built-in depth

44mm

Rated voltage

400V

Pollution degree

2

Current limiting class

3

Rated insulation voltage Ui

500V

Voltage type

AC

Release characteristic

C

Rated current

1A

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Concurrently switching neutral conductor

Additional equipment possible

Number of protected poles

3

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Suitable for flush-mounted installation