Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Built-in depth44mm
Width in number of modular spacings3
Frequency50 - 60Hz
Release characteristicD
Current limiting class-
Rated current16A
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Rated voltage400V
Over voltage category-
Pollution degree2
Number of poles (total)3
Connectable conductor cross section solid-core1.5 - 35mm²
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationYes
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of protected poles3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section multi-wired1.5 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408089 | AUT.OSIG. DX3 3P D16 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Built-in depth

44mm

Width in number of modular spacings

3

Frequency

50 .. 60Hz

Release characteristic

D

Current limiting class

-

Rated current

16A

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Rated voltage

400V

Over voltage category

-

Pollution degree

2

Number of poles (total)

3

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of protected poles

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.