Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Built-in depth47mm
Suitable for flush-mounted installationYes
Width in number of modular spacings4.5
Rated voltage400V
Rated current100A
Release characteristicC
Ambient temperature during operating-25 - 70°C
Number of protected poles3
Connectable conductor cross section multi-wired6 - 50mm²
Connectable conductor cross section solid-core6 - 70mm²
Number of poles (total)3
Over voltage category-
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408663 | AUT.OSIG. DX3 3P C100 16KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Built-in depth

47mm

Suitable for flush-mounted installation

Width in number of modular spacings

4.5

Rated voltage

400V

Rated current

100A

Release characteristic

C

Ambient temperature during operating

-25 .. 70°C

Number of protected poles

3

Connectable conductor cross section multi-wired

6 .. 50mm²

Connectable conductor cross section solid-core

6 .. 70mm²

Number of poles (total)

3

Over voltage category

-

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA