Rated current80A
Rated voltage400V
Built-in depth47mm
Voltage typeAC
Release characteristicC
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Suitable for flush-mounted installationYes
Over voltage category-
Pollution degree3
Current limiting class-
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Number of protected poles3
Width in number of modular spacings6
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Connectable conductor cross section multi-wired6 - 50mm²
Connectable conductor cross section solid-core6 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 70°C
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408703 | AUT.OSIG. DX3 4P C80 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current

80A

Rated voltage

400V

Built-in depth

47mm

Voltage type

AC

Release characteristic

C

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Suitable for flush-mounted installation

Over voltage category

-

Pollution degree

3

Current limiting class

-

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of protected poles

3

Width in number of modular spacings

6

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Connectable conductor cross section multi-wired

6 .. 50mm²

Connectable conductor cross section solid-core

6 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 70°C

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Additional equipment possible