Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Release characteristicD
Built-in depth47mm
Rated current125A
Voltage typeAC
Rated insulation voltage Ui500V
Rated voltage400V
Current limiting class-
Frequency50 - 60Hz
Pollution degree3
Connectable conductor cross section multi-wired6 - 50mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core6 - 70mm²
Number of protected poles3
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 70°C
Number of poles (total)3
Over voltage category-
Additional equipment possibleYes
Width in number of modular spacings4.5
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408771 | AUT.OSIG. DX3 4P D125 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Release characteristic

D

Built-in depth

47mm

Rated current

125A

Voltage type

AC

Rated insulation voltage Ui

500V

Rated voltage

400V

Current limiting class

-

Frequency

50 .. 60Hz

Pollution degree

3

Connectable conductor cross section multi-wired

6 .. 50mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

6 .. 70mm²

Number of protected poles

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 70°C

Number of poles (total)

3

Over voltage category

-

Additional equipment possible

Width in number of modular spacings

4.5

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.