Voltage typeAC
Built-in depth44mm
Rated voltage400V
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Over voltage category-
Current limiting class3
Connectable conductor cross section solid-core1.5 - 35mm²
Pollution degree2
Number of protected poles2
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired1.5 - 25mm²
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Rated current6A
Release characteristicB
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408939 | Aut.osig. DX3 2P B6 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Built-in depth

44mm

Rated voltage

400V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Over voltage category

-

Current limiting class

3

Connectable conductor cross section solid-core

1.5 .. 35mm²

Pollution degree

2

Number of protected poles

2

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Additional equipment possible

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Rated current

6A

Release characteristic

B

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA