Built-in depth44mm
Rated voltage400V
Voltage typeAC
Frequency50 - 60Hz
Rated current32A
Over voltage category-
Current limiting class3
Release characteristicB
Rated insulation voltage Ui500V
Number of protected poles2
Pollution degree2
Width in number of modular spacings2
Degree of protection (IP)IP20
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Ambient temperature during operating-25 - 70°C
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1.5 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408945 | AUT.OSIG. DX3 2P B32 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Rated voltage

400V

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

32A

Over voltage category

-

Current limiting class

3

Release characteristic

B

Rated insulation voltage Ui

500V

Number of protected poles

2

Pollution degree

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Ambient temperature during operating

-25 .. 70°C

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation