Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Frequency50 - 60Hz
Over voltage category-
Rated insulation voltage Ui500V
Pollution degree2
Release characteristicB
Width in number of modular spacings3
Degree of protection (IP)IP20
Rated current10A
Current limiting class3
Voltage typeAC
Rated voltage400V
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Number of poles (total)3
Additional equipment possibleYes
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Connectable conductor cross section solid-core1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

408989 | AUT.OSIG. DX3 3P B10 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Frequency

50 .. 60Hz

Over voltage category

-

Rated insulation voltage Ui

500V

Pollution degree

2

Release characteristic

B

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Rated current

10A

Current limiting class

3

Voltage type

AC

Rated voltage

400V

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Number of poles (total)

3

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Connectable conductor cross section solid-core

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.