Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Frequency50 - 60Hz
Rated current13A
Voltage typeAC
Rated voltage400V
Width in number of modular spacings4
Pollution degree2
Release characteristicB
Number of protected poles3
Degree of protection (IP)IP20
Current limiting class3
Rated insulation voltage Ui500V
Over voltage category-
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1.5 - 35mm²
Connectable conductor cross section multi-wired1.5 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Number of poles (total)4
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409064 | AUT.OSIG. DX3 4P B13 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Frequency

50 .. 60Hz

Rated current

13A

Voltage type

AC

Rated voltage

400V

Width in number of modular spacings

4

Pollution degree

2

Release characteristic

B

Number of protected poles

3

Degree of protection (IP)

IP20

Current limiting class

3

Rated insulation voltage Ui

500V

Over voltage category

-

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1.5 .. 35mm²

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Number of poles (total)

4

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.