Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated voltage400V
Frequency50 - 60Hz
Built-in depth44mm
Rated current20A
Release characteristicB
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 70°C
Width in number of modular spacings4
Connectable conductor cross section multi-wired1.5 - 25mm²
Connectable conductor cross section solid-core1.5 - 35mm²
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Pollution degree2
Current limiting class3
Suitable for flush-mounted installationYes
Rated insulation voltage Ui500V
Number of protected poles3
Concurrently switching neutral conductorYes
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409066 | AUT.OSIG. DX3 4P B20 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

44mm

Rated current

20A

Release characteristic

B

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 70°C

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Connectable conductor cross section solid-core

1.5 .. 35mm²

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Pollution degree

2

Current limiting class

3

Suitable for flush-mounted installation

Rated insulation voltage Ui

500V

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.