Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Rated current50A
Rated voltage400V
Built-in depth44mm
Concurrently switching neutral conductorYes
Current limiting class3
Pollution degree2
Number of protected poles3
Number of poles (total)4
Connectable conductor cross section solid-core1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Additional equipment possibleYes
Rated insulation voltage Ui500V
Release characteristicB
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Degree of protection (IP)IP20
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409070 | AUT.OSIG. DX3 4P B50 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

50A

Rated voltage

400V

Built-in depth

44mm

Concurrently switching neutral conductor

Current limiting class

3

Pollution degree

2

Number of protected poles

3

Number of poles (total)

4

Connectable conductor cross section solid-core

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Additional equipment possible

Rated insulation voltage Ui

500V

Release characteristic

B

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Degree of protection (IP)

IP20

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Width in number of modular spacings

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.