Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage400V
Built-in depth47mm
Current limiting class-
Frequency50 - 60Hz
Release characteristicB
Voltage typeAC
Rated insulation voltage Ui500V
Rated current100A
Pollution degree2
Width in number of modular spacings6
Number of protected poles3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Over voltage category-
Connectable conductor cross section multi-wired1.5 - 25mm²
Connectable conductor cross section solid-core1.5 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)4
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409090 | DX3 AUTOM OSIG 4P B100 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Built-in depth

47mm

Current limiting class

-

Frequency

50 .. 60Hz

Release characteristic

B

Voltage type

AC

Rated insulation voltage Ui

500V

Rated current

100A

Pollution degree

2

Width in number of modular spacings

6

Number of protected poles

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

-

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Connectable conductor cross section solid-core

1.5 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

4

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.