Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Voltage typeAC
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Rated current40A
Rated voltage230V
Release characteristicC
Current limiting class3
Over voltage category-
Width in number of modular spacings1
Number of protected poles1
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1.5 - 25mm²
Connectable conductor cross section solid-core1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Suitable for flush-mounted installationYes
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409118 | AUT.OSIG. DX3 1P C40 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Voltage type

AC

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Rated current

40A

Rated voltage

230V

Release characteristic

C

Current limiting class

3

Over voltage category

-

Width in number of modular spacings

1

Number of protected poles

1

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Connectable conductor cross section solid-core

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Suitable for flush-mounted installation

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.