Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Degree of protection (IP)IP20
Over voltage category-
Rated current10A
Rated insulation voltage Ui500V
Width in number of modular spacings2
Rated voltage400V
Current limiting class3
Built-in depth44mm
Release characteristicC
Frequency50 - 60Hz
Pollution degree2
Connectable conductor cross section multi-wired1.5 - 25mm²
Additional equipment possibleYes
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section solid-core1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Number of protected poles2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409200 | AUT.OSIG. DX3 2P C10 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Degree of protection (IP)

IP20

Over voltage category

-

Rated current

10A

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Rated voltage

400V

Current limiting class

3

Built-in depth

44mm

Release characteristic

C

Frequency

50 .. 60Hz

Pollution degree

2

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Additional equipment possible

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section solid-core

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Number of protected poles

2