Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current32A
Rated voltage400V
Frequency50 - 60Hz
Built-in depth44mm
Voltage typeAC
Current limiting class3
Rated insulation voltage Ui500V
Release characteristicC
Number of protected poles3
Connectable conductor cross section multi-wired1.5 - 25mm²
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Pollution degree2
Connectable conductor cross section solid-core1.5 - 35mm²
Over voltage category-
Width in number of modular spacings3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)3
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409257 | AUT.OSIG. DX3 3P C32 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current

32A

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

44mm

Voltage type

AC

Current limiting class

3

Rated insulation voltage Ui

500V

Release characteristic

C

Number of protected poles

3

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Concurrently switching neutral conductor

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Pollution degree

2

Connectable conductor cross section solid-core

1.5 .. 35mm²

Over voltage category

-

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.