Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency50 - 60Hz
Degree of protection (IP)IP20
Rated voltage400V
Rated current125A
Width in number of modular spacings4.5
Rated insulation voltage Ui500V
Voltage typeAC
Current limiting class-
Pollution degree3
Release characteristicC
Built-in depth47mm
Number of protected poles3
Over voltage category-
Connectable conductor cross section multi-wired1.5 - 25mm²
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Connectable conductor cross section solid-core1.5 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Number of poles (total)3
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409282 | DX3 AUTOM OSIG 3P C125 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Rated voltage

400V

Rated current

125A

Width in number of modular spacings

4.5

Rated insulation voltage Ui

500V

Voltage type

AC

Current limiting class

-

Pollution degree

3

Release characteristic

C

Built-in depth

47mm

Number of protected poles

3

Over voltage category

-

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Number of poles (total)

3

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.