Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings6
Rated current100A
Concurrently switching neutral conductorYes
Rated voltage400V
Degree of protection (IP)IP20
Built-in depth47mm
Voltage typeAC
Number of protected poles3
Current limiting class-
Pollution degree2
Release characteristicC
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Over voltage category-
Connectable conductor cross section solid-core1.5 - 35mm²
Connectable conductor cross section multi-wired1.5 - 25mm²
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409363 | DX3 AUTOM OSIG 4P C100 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings

6

Rated current

100A

Concurrently switching neutral conductor

Rated voltage

400V

Degree of protection (IP)

IP20

Built-in depth

47mm

Voltage type

AC

Number of protected poles

3

Current limiting class

-

Pollution degree

2

Release characteristic

C

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Over voltage category

-

Connectable conductor cross section solid-core

1.5 .. 35mm²

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.