Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage230V
Built-in depth44mm
Rated current6A
Voltage typeAC
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section solid-core1.5 - 35mm²
Connectable conductor cross section multi-wired1.5 - 25mm²
Additional equipment possibleYes
Frequency50 - 60Hz
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Over voltage category-
Width in number of modular spacings1
Degree of protection (IP)IP20
Number of protected poles1
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicD
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree2
Ambient temperature during operating-25 - 70°C
Suitable for flush-mounted installationYes
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409428 | DX3 AUTOM OSIG 1P D6 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

230V

Built-in depth

44mm

Rated current

6A

Voltage type

AC

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section solid-core

1.5 .. 35mm²

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Additional equipment possible

Frequency

50 .. 60Hz

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Over voltage category

-

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Number of protected poles

1

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

D

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Ambient temperature during operating

-25 .. 70°C

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.