Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated current63A
Number of protected poles2
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired1.5 - 25mm²
Built-in depth44mm
Degree of protection (IP)IP20
Current limiting class-
Frequency50 - 60Hz
Over voltage category-
Rated voltage400V
Additional equipment possibleYes
Number of poles (total)2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Pollution degree2
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Rated insulation voltage Ui500V
Width in number of modular spacings2
Release characteristicD
Connectable conductor cross section solid-core1.5 - 35mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409457 | DX3 AUTOM OSIG 2P D63 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated current

63A

Number of protected poles

2

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Built-in depth

44mm

Degree of protection (IP)

IP20

Current limiting class

-

Frequency

50 .. 60Hz

Over voltage category

-

Rated voltage

400V

Additional equipment possible

Number of poles (total)

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Pollution degree

2

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Release characteristic

D

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated impulse withstand voltage Uimp

4kV