Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage400V
Release characteristicD
Built-in depth44mm
Rated current20A
Current limiting class-
Frequency50 - 60Hz
Voltage typeAC
Rated insulation voltage Ui500V
Width in number of modular spacings3
Pollution degree2
Over voltage category-
Number of protected poles3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V16kA
Connectable conductor cross section solid-core1.5 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409500 | DX3 AUTOM OSIG 3P D20 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Release characteristic

D

Built-in depth

44mm

Rated current

20A

Current limiting class

-

Frequency

50 .. 60Hz

Voltage type

AC

Rated insulation voltage Ui

500V

Width in number of modular spacings

3

Pollution degree

2

Over voltage category

-

Number of protected poles

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

16kA

Connectable conductor cross section solid-core

1.5 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

32kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.