Aleta.hr
Main Product Image

409566 | DX3 AUTOM OSIG DC 2P C8 16KA

Code: 1778486

ManufacturerLegrand
Catalog number409566
EAN code3245064095662

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeDC
Suitable for flush-mounted installationYes
Built-in depth44mm
Rated current8A
Width in number of modular spacings2
Rated voltage230V
Ambient temperature during operating-25 - 70°C
Release characteristicC
Connectable conductor cross section multi-wired1.5 - 25mm²
Number of protected poles2
Connectable conductor cross section solid-core1.5 - 35mm²
Rated insulation voltage Ui500V
Current limiting class-
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Additional equipment possibleYes
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Frequency- - -Hz
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Over voltage category-
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409566 | DX3 AUTOM OSIG DC 2P C8 16KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

DC

Suitable for flush-mounted installation

Built-in depth

44mm

Rated current

8A

Width in number of modular spacings

2

Rated voltage

230V

Ambient temperature during operating

-25 .. 70°C

Release characteristic

C

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Number of protected poles

2

Connectable conductor cross section solid-core

1.5 .. 35mm²

Rated insulation voltage Ui

500V

Current limiting class

-

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Additional equipment possible

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

- .. -Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Over voltage category

-

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.