Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Pollution degree3
Built-in depth44mm
Frequency50 - 60Hz
Rated current10A
Over voltage category-
Rated insulation voltage Ui500V
Rated voltage230V
Release characteristicC
Voltage typeAC
Current limiting class-
Width in number of modular spacings1
Number of protected poles1
Connectable conductor cross section solid-core1.5 - 35mm²
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired1.5 - 25mm²
Ambient temperature during operating-25 - 70°C
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409754 | AUT.OSIG. DX3 1P C10 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Pollution degree

3

Built-in depth

44mm

Frequency

50 .. 60Hz

Rated current

10A

Over voltage category

-

Rated insulation voltage Ui

500V

Rated voltage

230V

Release characteristic

C

Voltage type

AC

Current limiting class

-

Width in number of modular spacings

1

Number of protected poles

1

Connectable conductor cross section solid-core

1.5 .. 35mm²

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Ambient temperature during operating

-25 .. 70°C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.