Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth47mm
Release characteristicC
Number of protected poles2
Suitable for flush-mounted installationYes
Concurrently switching neutral conductorNo
Rated voltage400V
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Voltage typeAC
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings3
Connectable conductor cross section solid-core1.5 - 50mm²
Over voltage category-
Current limiting class-
Connectable conductor cross section multi-wired1.5 - 35mm²
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)2
Ambient temperature during operating-25 - 70°C
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409775 | AUT.OSIG. DX3 2P C80 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

47mm

Release characteristic

C

Number of protected poles

2

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Rated voltage

400V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Voltage type

AC

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Connectable conductor cross section solid-core

1.5 .. 50mm²

Over voltage category

-

Current limiting class

-

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Ambient temperature during operating

-25 .. 70°C

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.