Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Voltage typeAC
Release characteristicC
Rated voltage400V
Frequency50 - 60Hz
Rated current6A
Pollution degree3
Number of protected poles3
Width in number of modular spacings3
Rated insulation voltage Ui500V
Current limiting class-
Over voltage category-
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-25 - 70°C
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired1.5 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section solid-core1.5 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409779 | AUT.OSIG. DX3 3P C6 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Voltage type

AC

Release characteristic

C

Rated voltage

400V

Frequency

50 .. 60Hz

Rated current

6A

Pollution degree

3

Number of protected poles

3

Width in number of modular spacings

3

Rated insulation voltage Ui

500V

Current limiting class

-

Over voltage category

-

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-25 .. 70°C

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section solid-core

1.5 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.