Aleta.hr
Main Product Image

409799 | AUT.OSIG. DX3 4P C50 25KA

Code: 1778542

ManufacturerLegrand
Catalog number409799
EAN code3245064097994

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationYes
Rated voltage400V
Rated current50A
Width in number of modular spacings6
Built-in depth47mm
Release characteristicC
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 35mm²
Number of protected poles3
Connectable conductor cross section solid-core1.5 - 50mm²
Rated impulse withstand voltage Uimp6kV
Number of poles (total)4
Rated insulation voltage Ui500V
Current limiting class-
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Over voltage category-
Frequency50 - 60Hz
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409799 | AUT.OSIG. DX3 4P C50 25KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated voltage

400V

Rated current

50A

Width in number of modular spacings

6

Built-in depth

47mm

Release characteristic

C

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Number of protected poles

3

Connectable conductor cross section solid-core

1.5 .. 50mm²

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

4

Rated insulation voltage Ui

500V

Current limiting class

-

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Over voltage category

-

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.