Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth47mm
Voltage typeAC
Rated current40A
Current limiting class-
Release characteristicD
Frequency50 - 60Hz
Rated voltage230V
Rated insulation voltage Ui500V
Width in number of modular spacings1.5
Number of protected poles1
Pollution degree3
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1.5 - 50mm²
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section multi-wired1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Additional equipment possibleYes
Over voltage category-
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409811 | AUT.OSIG. DX3 1P D40 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

47mm

Voltage type

AC

Rated current

40A

Current limiting class

-

Release characteristic

D

Frequency

50 .. 60Hz

Rated voltage

230V

Rated insulation voltage Ui

500V

Width in number of modular spacings

1.5

Number of protected poles

1

Pollution degree

3

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1.5 .. 50mm²

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Additional equipment possible

Over voltage category

-

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.